Engineering & Inventions · Buildings & infrastructure
How buildings stand up
Every building has to carry its own weight, its contents and the wind down to the ground. Follow those loads through floors, beams, columns and foundations, and see what the soil underneath has to do.

What you will learn
- Tell apart the dead, live and environmental loads a building carries
- Trace a load path from a floor through beams and columns to the foundations
- Tell a load-bearing wall building from a frame building and say why tall buildings use frames
- Explain how bracing, shear walls and cores stop a building from leaning in the wind
Lesson 1 of 4 · 4 min
Where a building's weight goes
Stand on the top floor of an office tower. Your weight presses down, and so do the desk beside you and the floor itself. Wind pushes on the windows. Engineers sort these forces into types, because each behaves differently.
The dead load is weight that stays put. It's the structure itself plus fixed things like walls, plasterboard and the roof. The live load comes and goes, such as people, furniture and planters. It changes, and it can bounce or vibrate.
Environmental loads come from nature, such as wind, snow, rain and earthquakes. Wind pushes sideways, so a building has to resist more than weight pressing down.
Building codes set minimum loads for each type of building and place. Engineers then multiply the loads they expect by load factors, so the finished design is stronger than the worst load it should ever meet.
Every load needs a route to the ground, called the load path. Follow your desk. Its weight presses on the floor slab, and the slab passes it to the beams beneath. The beams carry it sideways to the columns. The columns carry it down, floor after floor, to the foundations.
Engineer Jim Tod compares the load path to a chain that's only as strong as its weakest link. Often that link is a connection, the bolts, welds or plate where two parts meet.
Leave out columns to open up an atrium, and their load doesn't vanish. It moves sideways and goes down the remaining columns. Wind takes its own route, through bracing, stiff walls or a core around the lifts.
Try to recallTrace the load path of a heavy desk on the fifth floor of an office building down to the ground.
The desk presses on the floor slab, which passes the weight to the beams under it. The beams carry it sideways to the columns. The columns carry it down through the floors below to the foundations, which pass it into the soil.
A building carries dead loads, live loads and the pushes of wind and snow. Each load follows a path from floor to beam to column to foundation and into the soil, and that path is only as strong as its weakest link.
Lessons in this topic
Where a building's weight goes
Learn the kinds of load a building carries, from its own weight to the wind, and follow one load from a desk all the way down into the soil.
Walls that hold you up and frames that free them
Compare buildings held up by their walls with buildings held up by a frame, and see how bracing and stiff walls stop either kind from leaning in the wind.
What the ground does, and what went wrong at Pisa
See why footings spread out and piles reach down, what settlement is, and how engineers worked out why the Leaning Tower of Pisa leaned and stopped it.
How to spot what holds a building up
Learn to read the structure in half-timbered, timber-framed and brick buildings, and see why some walls can't come out without something taking their place.
Three quick stories from this topic
The suspiciously light skyscraper
Chicago officials halted work on an early skyscraper because its frame made it so light
The Home Insurance Building, finished in 1885, weighed a third as much as a masonry building. Its metal skeleton carried the floors, so the walls no longer had to, and officials stopped construction to check it was safe.
How tall
It opened at ten stories and 138 feet. Two more floors in 1891 took it to 180 feet.
Its fate
It was demolished in 1931 to make way for the Field Building.
Six-foot brick walls
Chicago's 16-story Monadnock Building stands on brick walls 6 feet thick at the base
The walls thin to 18 inches at the top. Its designers judged this the tallest a load-bearing building could economically go, because thicker walls would have swallowed too much rentable floor space.
A record
At 215 feet, the Monadnock was the tallest commercial masonry building in the world when it was finished in the 1890s.
What replaced it
Frames of columns and beams carry the floors instead, so outer walls can be thin or even glass.
Pisa's tower pulled back
Engineers saved the Leaning Tower of Pisa by drilling soil out from under its high side
From 1999 to 2001, drills pulled small amounts of soil from beneath the north side. That side sank slightly and the tower rotated back about half a degree, too little to see but enough to make it safe.
Lead first
In 1993 engineers stacked 600 tonnes of lead on the high side as a stopgap, later raising it to 900 tonnes.
Why it leaned
The soft ground lacked stiffness. Past a critical height, any small tilt made a turning force the ground couldn't push back.
Sources
- Structural load, Wikipedia
- Understanding structural load paths, Institution of Civil Engineers, Knowledge Hub
- Home Insurance Building, Wikipedia
- Monadnock Building, Wikipedia
- Leaning Tower of Pisa: Behaviour after Stabilization Operations (2009), J. B. Burland, M. B. Jamiolkowski and C. Viggiani, International Journal of Geoengineering Case Histories
- Leaning Tower of Pisa, Wikipedia